Zonecheck is simple and sustainable solution for performing sprinkler system flow-switch tests.
Flow-switches installed on a sprinkler system are required to be tested on a quarterly basis, Conventionally during a routine test, water is discharged from the down stream end of the pipe, causing a drop in the pressure. This pressure difference across the flow-switch generates a water flow causing the flow-switch to operate.
Our Zonecheck system is the modern way to carry out this important test quickly, efficiently and inexpensively saving 100% of the water normally discharged to waste. Zonecheck simplifies testing by re-circulating the water within the pipe around the flow-switch, to simulate the flow of one sprinkler head in operation, regardless of where the Zonecheck is installed or located on the system. Zonecheck is simple and easy to use, requiring no specialist skills and this flow-switch test system can be operated at any time. It does not require evacuation of the building and therefore has no effect on normal functioning of the building.
Key-switch

“For a building with 50 flow-switches Zonecheck saves 64,000 liters of water a year. Also, as there is no water discharge, no fire pumps run to refill the system saving fuel and energy.”
System Benefits
With Zonecheck testing is easy. A fully code compliant test can be carried out via a simple key-switch.
Zonecheck is 100% water saving. It also indirectly save energy normally used to run large fire pumps to refill the system.
With Zonecheck, as no water is discharged, testing is easy, takes less time and requires no additional manpower.
Remote testing can be executed from a convenient location via the remote key-switch.
Zonecheck’s method of testing is the only way to accurately test to BS EN12845 code standards and only uses LPCB approved components.
Reduced maintenance, Zonecheck recirculates water within the pipe work reducing leaks and no fire pumps are run as a result of testing.
Models
Zonecheck
Automatic flow-switch tester, circulates water around the flow-switch so there is no need to discharge water. Comes in various models including Galvanised manifold.
Zonecheck Retro-fit
For retro-fit applications, fits around an existing flow-switch and circulates water around the it so there is no need to discharge water.
Key-switch
From the key-switch you can initiate a compliant test remotely simply by turning the key.
Pre-wired Loom
Pre-wired key-switch and loom for rapid site installation and commissioning.
Approvals
Zonecheck has been developed to comply with all fire sprinkler system code standards including BS EN 12845, NFPA and FM. Our Zonecheck flow-switch tester is approved by LPCB, FM, UL and VdS.
Videos
We are here to help
Want to know more about how you can simplify your testing routines?
If you want to contact a member of our team, please fill out the form or send an email to khlim@ecozonesingapore.com